How to ramp the high voltage

in workspace “Apfel+HV” find terminal Ramp HV:

ramp Detector HV up:

agmaas@prima-daq1:~/repo/hv_control$ python3 ramp_hv.py -f /data/data_raid/prima_feb_25/hv_scan_6 -x /home/agmaas/Data/beamtime_Feb2025/hv/exclude_channels.dat -id all -off -0

ramp Detector HV down:

agmaas@prima-daq1:~/repo/hv_control$ python3 ramp_hv.py -val 0 -x /home/agmaas/Data/beamtime_Feb2025/hv/exclude_channels.dat -id all

ramp pre-HV (ISEG) down or up:

  • MAKE SURE DETEKTOR HV IS OFF!
  • Go to webinterface→detector control → iseg high voltage (tab should be open in firefox already)
  • select the 5 rightmost modules one by one
  • Click checkbox “select all”
  • click “switch all <on/off>”