Call MAMI and tell them, that you want to check the beam position.
Ask MAMI to switch off the beam and wait for the confirmation, that the beam is off!
Move in the screen (see section: Change Target) go_Al2O3
on a1analyse (Computer with Dual screen) locate the upwards arrow on the panel next to the a1-logo
Click it to open the menu
Select the menu item Target Camera
An MPlayer window will open. If not, check if it's already open.
Press c
to activate the camera, now you should see the cross hairs on the screen.
Ask MAMI for a little bit of beam (nanoamperes)
When you see the beam on the screen, take a picture by pressing p
. It will be saved to the logbook.
Ask MAMI to center the beam on the target and take another picture.
Switch off the camera by pressing c
again. Close the MPlayer window.
Ask MAMI to switch off the beam and wait for the confirmation, that the beam is off!
Move in the correct production target (e.g. go_C12
)
Wait for the target to reach the position.
Check the target position with where_target
. The setpoint should be the selected target, and the difference should be small ( < 100 ).
Ask MAMI for the correct beam current.