-====== Front Cooling Plate ======+====== Front Cooling Plate Thickness ======
  
 The impact of a front cooling plate of aluminium on the energy resolution was studied. The cooling plate was placed in front of the crystals (distance: 3mm) and its thickness was varied between 0mm and 10mm.\\ The impact of a front cooling plate of aluminium on the energy resolution was studied. The cooling plate was placed in front of the crystals (distance: 3mm) and its thickness was varied between 0mm and 10mm.\\
Line 32: Line 32:
 {{:software:g4simulation:studies:crystal_setup_full_2.png?300|}} {{:software:g4simulation:studies:crystal_setup_full_2.png?300|}}
  
-The mean energy resolution and the std of those 8*16=128 inner crystals was calculated and plotted against the front cooling plate thickness.+The mean energy resolution and the std of those 8*16=128 inner crystals was calculated and plotted against the front cooling plate thickness. \\ 
 +The plots show a worsening of the energy resolution with a thicker cooling plate. But still the absolute difference for no cooling plate and a 10mm cooling plate is from 4.7% (3.04%) to 4.85% (3.12%) for an energy of 500Mev (1000MeV).
  
 {{:software:g4simulation:studies:en_res_500mev_inner_8_subm.png?330 |}} {{:software:g4simulation:studies:en_res_500mev_inner_8_subm.png?330 |}}