   * Link: ''http://hadanapc2:8081/dcs/iseg-hv''   * Link: ''http://hadanapc2:8081/dcs/iseg-hv''
-  * All channels in modules 5 to 9 should be on and set to 500 V.  
   * To select the channels corresponding to a specific submodule, click on the detector map.   * To select the channels corresponding to a specific submodule, click on the detector map.
  
-== +== Normal settings == 
 +  * All channels in modules 5 to 9 should be on and set to 500 V.  
 +  * When the HV boards are set to 0, typical currents are around 850 nA. 
 +  * During operation (HV on and beam on), currents around 2 µA. 
 + 
 +== Possible Issues == 
 +  * Channel trip due to high current 
 +  * Interlock signal off due to failure in LV power supply 
 + 
 +In both cases the whole crate needs to be restarted to resume operation: 
 + 
 + 1. Switch the crate off and on by clicking on the "Main Switch" on the picture. 
 + 
 + 2. Go to the bottom right terminal window on workspace ''APFEL-HV'' 
 + 
 +   agmaas@hadanapc2:~/repo/prima-web-interface/src/iseg_hv$ 
 + 
 + 3. Run the static settings script 
 + 
 +   python3 iseg_static_settings.py  
 + 
 + 