User Tools

Site Tools


prima_control:how_to_ramp_hv

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
prima_control:how_to_ramp_hv [2025/02/26 12:08] himuserprima_control:how_to_ramp_hv [2025/02/28 10:33] (current) himuser
Line 1: Line 1:
 ==== How to ramp the high voltage == ==== How to ramp the high voltage ==
  
-in workspace "Apfel+HV" find terminal Ramp HV: 
  
-ramp HV up: +=== Ramp detector HV === 
 + 
 + 
 +== ramp Detector HV up: ==  
 +1) check that HV on ISEG is ramped up to 500V; IF NOT, RAMP UP (SEE BELOW) 
 + 
 +2) ramp up detector HV: 
 + 
 +in workspace "Apfel+HV" find terminal Ramp HV:
 <code> <code>
 agmaas@prima-daq1:~/repo/hv_control$ python3 ramp_hv.py -f /data/data_raid/prima_feb_25/hv_scan_6 -x /home/agmaas/Data/beamtime_Feb2025/hv/exclude_channels.dat -id all -off -0 agmaas@prima-daq1:~/repo/hv_control$ python3 ramp_hv.py -f /data/data_raid/prima_feb_25/hv_scan_6 -x /home/agmaas/Data/beamtime_Feb2025/hv/exclude_channels.dat -id all -off -0
 </code> </code>
  
-ramp HV down:+ 
 +== ramp Detector HV down: == 
 + 
 +1) ramp down HV on APDs
 <code> <code>
 agmaas@prima-daq1:~/repo/hv_control$ python3 ramp_hv.py -val 0 -x /home/agmaas/Data/beamtime_Feb2025/hv/exclude_channels.dat -id all agmaas@prima-daq1:~/repo/hv_control$ python3 ramp_hv.py -val 0 -x /home/agmaas/Data/beamtime_Feb2025/hv/exclude_channels.dat -id all
 </code> </code>
 +if the last line of the output is a 1 repeatedly, you can stop the terminal "Crt+c"
 +
 +
 +**--------------------------------------------------------------------------------------------------------------------------------------------------**
 +
 +
 +=== Ramp ISEG HV ===
 +
 +== ramp pre-HV (ISEG) up: ==
 +
 +1) **check that detector hv is off**
 +
 +2) use web interface (tab should be open in firefox already)
 +
 +IF NOT: http://hadanapc2:8081/dcs/iseg-hv
 +
 +3) for modules 5 to 9, click checkbox "select all" and click "switch all <on/off>"
 +
 +
 +== ramp pre-HV (ISEG) down: ==
 +
 +1) **check that detector hv is off**
 +
 +2) use web interface (tab should be open in firefox already)
 +
 +IF NOT: http://hadanapc2:8081/dcs/iseg-hv
 +
 +3) for modules 5 to 9, click checkbox "select all" and click "switch all <on/off>"
 +
 +
  
 +  
  
-{{:prima_control:screenshot_2025-02-26_13-00-08.png?500|}}+{{:prima_control:screenshot_2025-02-26_13-08-57.png?600|}}
  
  
  
prima_control/how_to_ramp_hv.1740571711.txt.gz · Last modified: 2025/02/26 12:08 by himuser

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki