beamtimes:2022_apr:a1 [2022/04/20 14:43] himuserbeamtimes:2022_apr:a1 [2022/04/21 15:16] (current) himuser
Line 2: Line 2:
  
 ==== Change Target ==== ==== Change Target ====
-* Make sure the beam is off! Usually one moves the target only while being on the phone to MAMI. +  * Make sure the beam is off! Usually one moves the target only while being on the phone to MAMI. 
-* Open a terminal as mezzo on control1 +  * Open a terminal as mezzo on control1 
-* Optional: Check the target position with where_target +  * Optional: Check the target position with ''where_target'' 
-* Go to the new position with the appropriate go-command (e.g. go_C12) +  * Go to the new position with the appropriate go-command (e.g. ''go_C12''
-* Check the target position with where_target. The setpoint should be the selected target, and the difference should be small ( < 100 )+  * Check the target position with ''where_target''. The setpoint should be the selected target, and the difference should be small ( < 100 )
  
  
 === Checking Beam Position === === Checking Beam Position ===
- +  * Call MAMI and tell them, that you want to check the beam position. 
-* Call MAMI and tell them, that you want to check the beam position. +  * **Ask MAMI to switch off the beam and wait for the confirmation, that the beam is off!** 
-'''Ask MAMI to switch off the beam and wait for the confirmation, that the beam is off!''' +  * Move in the screen (see section: **Change Target**) ''go_Al2O3'' 
-* Move in the screen (see section: ''Moving the Target'') +  * on a1analyse (Computer with Dual screen) locate the upwards arrow on the panel next to the a1-logo 
-* on a1analyse (Computer with Dual screen) locate the upwards arrow on the panel next to the a1-logo +    * Click it to open the menu 
-** Click it to open the menu +    * Select the menu item ''Target Camera'' 
-** Select the menu item ''Target Camera'' +    * An MPlayer window will open. If not, check if it's already open. 
-** An MPlayer window will open. If not, check if it's already open. +  * Press ''c'' to activate the camera, now you should see the cross hairs on the screen. 
-* Press 'c' to activate the camera, now you should see the cross hairs on the screen. +  * Ask MAMI for a little bit of beam (nanoamperes) 
-* Ask MAMI for a little bit of beam (nanoamperes) +  * When you see the beam on the screen, take a picture by pressing ''p''. It will be saved to the logbook. 
-* When you see the beam on the screen, take a picture by pressing 'p'. It will be saved to the logbook. +  * Ask MAMI to center the beam on the target and take another picture. 
-* Ask MAMI to center the beam on the target and take another picture. +  * **Switch off the camera** by pressing ''c'' again. Close the MPlayer window. 
-'''Switch off the camera by pressing 'c' again.''' Close the MPlayer window. +  * **Ask MAMI to switch off the beam and wait for the confirmation, that the beam is off!** 
-'''Ask MAMI to switch off the beam and wait for the confirmation, that the beam is off!''' +  * Move in the correct production target (e.g. ''go_C12''
-* Move in the correct production target (e.g. ''go_C12''+  * Wait for the target to reach the position. 
-* Wait for the target to reach the position. +  * Check the target position with ''where_target''. The setpoint should be the selected target, and the difference should be small ( < 100 ). 
-* Check the target position with ''where_target''. The setpoint should be the selected target, and the difference should be small ( < 100 ). +  * Ask MAMI for the correct beam current.
-* Ask MAMI for the correct beam current.+
  
 ==== Spec A ==== ==== Spec A ====