beamtimes:2018_jan
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
beamtimes:2018_jan [2018/02/01 07:28] – [General Overview] himuser | beamtimes:2018_jan [2022/01/14 18:44] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 10: | Line 10: | ||
The bottles are placed in the detector lab in the A1 ground floor. | The bottles are placed in the detector lab in the A1 ground floor. | ||
- | ^Pres /bar ^ date ^ | + | ^ Pres /bar ^ date ^ |
- | | 105 | 31.01. 15:55 | | + | | 105 | 31.01. 15:55 | |
+ | | 75 | 1.2. 10:00 | | ||
+ | | 50 | 2.2. 00:01 | | ||
+ | | 48 | 2.2. 04:00 | | ||
+ | | 175 | 4.6. 17:10 | | ||
+ | | 150 | 5.6. 13:00 | | ||
+ | | 100 | 6.6. 20:00 | | ||
+ | | 100 | 6.6. 22:15 | | ||
+ | | 85 | 7.6. 05:10 | | ||
+ | | 65 | 7.6. 15:45 | | ||
+ | | 55 | 7.6. 20:00 | | ||
+ | | 40 | 8.6. 01:20 | | ||
+ | | 35 | 8.6. 04:05 | | ||
+ | | 29 | 8.6. 06:45 | | ||
+ | | 20 | 8.6. 10:45 | | ||
+ | | new | bottle | ||
+ | | 210 | 8.6. 13:45 | ||
==== General Overview ==== | ==== General Overview ==== | ||
Line 20: | Line 36: | ||
- start with smallest current (1 nA) | - start with smallest current (1 nA) | ||
- if event rate too high: install picoamperemeter | - if event rate too high: install picoamperemeter | ||
+ | |||
===2 Preparation with C, 1.5 GeV, smallest angle=== | ===2 Preparation with C, 1.5 GeV, smallest angle=== | ||
Line 38: | Line 55: | ||
- recognise one or more energy peaks | - recognise one or more energy peaks | ||
- | - elastic on C (nucleus) | + | * elastic on C (nucleus) |
- | elastic on H | + | |
- | inelastic on H in coinc. with spec. A | + | |
- | adjust HV | + | |
- | change angle or spec. A settings for changing the peak energy | + | |
+ | |||
===4 Total rate and global spectrum with Ta=== | ===4 Total rate and global spectrum with Ta=== | ||
- | vary beam current -> find appropriate value | + | - vary beam current -> find appropriate value |
- | threshold scan at the smallest angle | + | |
- | vary scattering angles | + | |
===5 Identify pi0 events (measuring gammas)=== | ===5 Identify pi0 events (measuring gammas)=== | ||
- | use second scintillator at different angles for electrons | + | - use second scintillator at different angles for electrons |
- | set up triple coincidence | + | |
- | change spec. A polarity to measure electrons | + | |
- | set up coincidence with spec. A | + | |
- | measure gamma spectrum changing angle and spectrometer settings (measure end-point of the gamma spectrum) | + | |
- | try different targets C,CH2,Ta | + | |
===6 Measurements with 855 MeV=== | ===6 Measurements with 855 MeV=== | ||
- | change beam energy (until Friday noon!) | + | - change beam energy (until Friday noon!) |
- | increase beam current to appropriate value | + | |
- | repeat measurements for energy calibration | + | |
- | repeat measurements for total rate | + | |
- | repeat measurements for pi0 event identification | + | |
+ |
beamtimes/2018_jan.1517470088.txt.gz · Last modified: 2022/01/14 18:44 (external edit)