beamtimes:2018_jan

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
beamtimes:2018_jan [2018/01/31 16:26] – [Nitrogen] adminbeamtimes:2018_jan [2022/01/14 18:44] (current) – external edit 127.0.0.1
Line 10: Line 10:
 The bottles are placed in the detector lab in the A1 ground floor. The bottles are placed in the detector lab in the A1 ground floor.
  
-^Pres /bar ^ date ^ +^ Pres /bar  ^ date          
-| 105 | 31.01. 15:55 |+| 105        | 31.01. 15:55  | 
 +| 75         | 1.2. 10:00    | 
 +| 50         | 2.2. 00:01    | 
 +| 48         | 2.2. 04:00    | 
 +| 175        | 4.6. 17:10    | 
 +| 150        | 5.6. 13:00    | 
 +| 100        | 6.6. 20:00    | 
 +| 100        | 6.6. 22:15    | 
 +| 85         | 7.6. 05:10    | 
 +| 65         | 7.6. 15:45    | 
 +| 55         | 7.6.  20:00   | 
 +| 40         | 8.6.  01:20   | 
 +| 35         | 8.6.  04:05   | 
 +| 29         | 8.6.  06:45   | 
 +| 20         | 8.6. 10:45    | 
 +| new        | bottle        | 
 +| 210        | 8.6. 13:45    |
 ==== General Overview ==== ==== General Overview ====
  
Line 18: Line 34:
 ===1 Get beam=== ===1 Get beam===
  
-start with smallest current (1 nA) +  - start with smallest current (1 nA) 
-if event rate too high: install picoamperemeter+  if event rate too high: install picoamperemeter 
 ===2 Preparation with C, 1.5 GeV, smallest angle=== ===2 Preparation with C, 1.5 GeV, smallest angle===
  
 For each setting: For each setting:
  
-measure rates +  * measure rates 
-take spectrum (look at gamma and e spectra)+  take spectrum (look at gamma and e spectra) 
 Steps: Steps:
  
-set up coincidence between EMC and scintillator +  - set up coincidence between EMC and scintillator 
-increase beam current up to 100 nA in various steps -> find appropriate current value +  increase beam current up to 100 nA in various steps -> find appropriate current value 
-change thresholds +  change thresholds 
-move prototype with the xy table +  move prototype with the xy table 
-set up coincidence with spectrometer A+  set up coincidence with spectrometer A 
 ===3 HV and energy calibration (plastic target)=== ===3 HV and energy calibration (plastic target)===
  
-recognise one or more energy peaks +  - recognise one or more energy peaks 
-elastic on C (nucleus) +    elastic on C (nucleus) 
-elastic on H +    elastic on H 
-inelastic on H in coinc. with spec. A +    inelastic on H in coinc. with spec. A 
-adjust HV +  adjust HV 
-change angle or spec. A settings for changing the peak energy+  change angle or spec. A settings for changing the peak energy 
 + 
 ===4 Total rate and global spectrum with Ta=== ===4 Total rate and global spectrum with Ta===
  
-vary beam current -> find appropriate value +  - vary beam current -> find appropriate value 
-threshold scan at the smallest angle +  threshold scan at the smallest angle 
-vary scattering angles+  vary scattering angles
  
 ===5 Identify pi0 events (measuring gammas)=== ===5 Identify pi0 events (measuring gammas)===
  
-use second scintillator at different angles for electrons +  - use second scintillator at different angles for electrons 
-set up triple coincidence +  set up triple coincidence 
-change spec. A polarity to measure electrons +  change spec. A polarity to measure electrons 
-set up coincidence with spec. A +  set up coincidence with spec. A 
-measure gamma spectrum changing angle and spectrometer settings (measure end-point of the gamma spectrum) +  measure gamma spectrum changing angle and spectrometer settings (measure end-point of the gamma spectrum) 
-try different targets C,CH2,Ta+  try different targets C,CH2,Ta
  
 ===6 Measurements with 855 MeV=== ===6 Measurements with 855 MeV===
  
- change beam energy (until Friday noon!) +  - change beam energy (until Friday noon!) 
-increase beam current to appropriate value +  increase beam current to appropriate value 
-repeat measurements for energy calibration +  repeat measurements for energy calibration 
-repeat measurements for total rate +  repeat measurements for total rate 
-repeat measurements for pi0 event identification+  repeat measurements for pi0 event identification 
 + 